Indoor Three Core

Heat shrinkable termination kit designed for indoor termination of three-core medium-voltage cables. Suitable for XLPE-insulated, sheathed or armoured cables, it provides electrical stress control, anti-tracking insulation, moisture sealing and earth connection for reliable cable termination.
33 kV
11 kV
22 kV
XLPE
MV Cable
Armoured Cable
Wire Screen Cable
Stress Control
Anti-Tracking
Rain Sheds
Cable Screen
Earth Connection

Selection Summary

Application : Indoor

Cable Insulation : XLPE

Material : Crosslinked Polyolefins

Voltage Range : 11 kV to 33 kV

Cable Construction : Sheathed or Armoured

Semi-Conductive Layer : Removable or Strippable

Earth Connection : Soldered or Solderless

Application Check

Is this product right for your application?

Application

Suitable?

Recommendation

Three-Core Cable
Yes
Use Three-Core Termination Kit
Single-Core Cable
No
Use Single-Core Termination Kit
Indoor Installation
Yes
Suitable for indoor termination
Outdoor Installation
No
Use Outdoor Termination Kit
11 kV System
Yes
Select kit by cable size
22 kV System
Yes
Select kit by cable size
33 kV System
Yes
Select kit by cable size
Armoured Cable
Yes
Select suitable earth connection
Wire-Screen Cable
Yes
Screen wires can be accommodated

SPECIFICATIONS

Technical Specifications

Nominal voltage U0/U(Um) Cross section (mm2) Dimensions L (mm) Dimensions D (mm) No. of rain sheds
3.6 / 6(7.2)kV 50-120 750 – 0
3.6 / 6(7.2)kV 150-240 750 – 0
3.6 / 6(7.2)kV 300-400 750 – 0
3.6 / 6(7.2)kV 500 750 – 0
6 / 10(12)kV 50 -95 750 – 0
6.35 / 11(12)kV 120-185 750 – 0
6.35 / 11(12)kV 240-300 750 – 0
6.35 / 11(12)kV 400-500 750 – 0
6.35 / 11(12)kV 630 750 – 0
8.7 / 15(17.5)kV 25-50 750 – 0
8.7 / 15(17.5)kV 70-120 750 – 0
8.7 / 15(17.5)kV 150-240 750 – 0
8.7 / 15(17.5)kV 300-400 750 – 0
8.7 / 15(17.5)kV 500-630 750 – 0
12 / 20(24)kV 35-50 900 105 6
12.7 / 22(24)kV 70-120 900 105 6
12.7 / 22(24)kV 150-240 900 105 6
12.7 / 22(24)kV 300-400 900 140 6
12.7 / 22(24)kV 500-630 900 140 6
18 / 30(36)kV 35-50 1100 105 12
19 / 33(36)kV 70-120 1100 105 12
19 / 33(36)kV 150-240 1100 140 12
19 / 33(36)kV 300-400 1100 140 12
19 / 33(36)kV 500-630 1100 140 12
20.8 / 36(42)kV 50 1100 140 12
26 / 35(42)kV 70-120 1100 140 12
26 / 35(42)kV 150-240 1100 140 12
26 / 35(42)kV 300-400 1100 140 12
26 / 35(42)kV 500-630 1100 140 12

Request Quotation

FAQS

Frequently Asked Questions

Find quick answers to common questions about our programs, admissions, eligibility, and application process to help you move forward with confidence.

A heat shrink termination kit insulates, seals, and terminates medium-voltage power cables at equipment such as switchgear, transformers, and other electrical installations. It helps maintain electrical insulation while protecting the cable end from moisture and environmental exposure.
Select a kit based on the cable voltage, cable type (single-core or three-core), conductor size, armouring, insulation type, and whether the installation is indoors or outdoors. Always ensure compatibility with the cable manufacturer's specifications.
Indoor termination kits are designed for installations protected from weather. Outdoor kits include additional weather-resistant insulation and sealing components to withstand UV exposure, rain, and other environmental conditions.
Axis heat shrink termination kits are available for medium-voltage cable systems from 11 kV to 33 kV, with configurations for both single-core and three-core cables.

Download Catalogue