Pre-Insulated Midspan Joints

Pre-Insulated Midspan Joints connect two insulated phase or neutral conductors in Aerial Bundled Cable systems while maintaining electrical continuity and mechanical strength. The aluminium barrel is prefilled with oxide-inhibiting compound, while the UV- and weather-resistant insulation provides a sealed connection for outdoor installations.
Aerial Bundled Cable
Phase Conductor
Neutral Conductor
Hexagonal Crimping
Cable Jointing
Inline Cable Connection

Selection Summary

Cable Size : 10–150 mm²

Neutral Sizes : 54.6 / 70 mm²

Cable Diameter : 4.5–15.5 mm

Crimping : Standard Hexagonal Dies

Identification : Colour Coded by Cable Size

Certificates & Approvals

NF C 33-021

Application Check

Is this product right for your application?

Application

Suitable?

Recommendation

10–150 mm² Insulated Phase Cable
Yes
Select joint according to cable size
54.6 mm² Neutral Conductor
Yes
Select MSJN0050
70 mm² Neutral Conductor
Yes
Select MSJN0070
Joining Two AB Cable Ends
Yes
Use for inline cable joining
Outdoor Installation
Yes
UV- and weather-resistant insulation
Standard Hexagonal Crimping
Yes
Crimp at the marked locations
Cable Tap-Off
No
Use an Insulation Piercing Connector instead

SPECIFICATIONS

Technical Specifications

Product Code Cable Size Colour Code Cable Dia
MSJ0010 10 mm² Green 4.5 mm
MSJ0016 16 mm² Blue 5.5 mm
MSJ0025 25 mm² Orange 6.5 mm
MSJ0035 35 mm² Red 8.0 mm
MSJ0050 50 mm² Yellow 9.7 mm
MSJ0070 70 mm² White 11.0 mm
MSJ0095 95 mm² Grey 12.5 mm
MSJ0120 120 mm² Pink 14.0 mm
MSJ0150 150 mm² Violet 15.5 mm
MSJN0050 54.6 mm² (N) Black 9.6 mm
MSJN0070 70 mm² (N) White 11.0 mm

Request Quotation

FAQS

Frequently Asked Questions

Find quick answers to common questions about our programs, admissions, eligibility, and application process to help you move forward with confidence.

The range covers insulated phase conductors from 10 mm² to 150 mm², along with dedicated 54.6 mm² and 70 mm² neutral conductor variants.
They are used to join two insulated phase or neutral conductors in an Aerial Bundled Cable system.
Yes. Each cable end must be stripped to the specified insertion length before being inserted and crimped.
The joints are designed for crimping with standard hexagonal dies at the marked crimping locations.
The aluminium barrel is factory-filled with an oxide-inhibiting compound.
Each size has a specific colour code, ranging from green for 10 mm² to violet for 150 mm², with separate colour identification for neutral conductor variants.

Download Catalogue