home > Lightning Protection > Surge Protection Devices > Type 1+2 Surge Protection Device

Type 1+2 Surge Protection Device

Type 1+2 Surge Protection Device (Class B+C) complies with IEC 61643-31 and protects electrical systems from voltage spikes and transient surges caused by lightning strikes, switching operations and electrostatic discharges. Available for single phase and three phase systems.
Lightning Protection
Surge Protection Device
SPD
Type 1 SPD
Type 2 SPD
Type 1+2 SPD
IEC 61643-31
Overvoltage Protection

Selection Summary

Type : Type 1+2

Class : B+C

Phase : Single Phase, Three Phase

Power Supply : 230V AC, 415V AC

Max Continuous Operating Voltage (Uc) : 320V

Standard : IEC 61643-31

Application Check

Is this SPD right for your installation?

Application

Suitable?

Recommendation

Panels where cables enter from outside the building
Yes
Select Type 1+2 (Class B+C), 12.5 kA Iimp per pole

SPECIFICATIONS

Technical Specifications

Product Code Type Class Max Continuous Operating Voltage Uc Voltage Protection Level L-N / N-PE (KV) Lightning Impulse Current Iimp (KA) per pole Nominal Discharge Current In (KA) per pole Max Discharge Current Imax (KA) per pole Response Time (ns) Power Supply Phase
ASPDA2P32060 1+2 B+C 320V 1.5 KV between phase to neutral and neutral to earth 12.5 30 60 25 230V AC Single Phase Application
ASPDA4P32060 1+2 B+C 320V 1.5 KV between phase to neutral and neutral to earth 12.5 30 60 25 415V AC Three Phase Application

Request Quotation

FAQS

Frequently Asked Questions

Find quick answers to common questions about our programs, admissions, eligibility, and application process to help you move forward with confidence.

SPDs shield electrical equipment from voltage spikes caused by lightning strikes, power surges or switching operations. They limit transient overvoltage and divert surge currents, protecting sensitive components and extending the life of electrical systems.
Yes. Axis SPDs are designed in accordance with IEC 61643-31.
Type 1 (Class B) SPDs handle high-energy lightning surges and are installed at the main service entrance. Type 2 (Class C) SPDs use MOVs, respond faster with lower energy handling, and are installed in distribution panels downstream of the main panel.
A Type 1+2 (Class B+C) SPD is installed in panels where cables enter from outside the building. It combines Metal Oxide Varistors and spark gaps, performs similar functions to Type 1 and is more economical.
Consider the system voltage, whether the supply is single phase or three phase, the exposure to direct or indirect surges, and the installation location. Axis provides technical guidance and product specifications to help you select the right model.
Yes. SPDs protect photovoltaic panels and inverters from voltage surges caused by lightning or grid disturbances.

Download Catalogue