Heavy Wall Heat Shrink Tube (MV)

Heavy wall heat shrink tubes provide insulation, mechanical protection and environmental sealing for medium-voltage cable applications. Their crosslinked polyolefin body and thermoplastic adhesive lining resist moisture, abrasion and impact in underground, direct-burial and submersible installations.
Chemical Resistance
MV
Electrical Sleeving
Cable Repair
Protective Jacket

Selection Summary

Voltage Class : Medium Voltage

Material : Crosslinked Polyolefin

Lining : Thermoplastic Adhesive

Operating Temperature : −45°C to +110°C

Size Selection : Supplied and Recovered Inner Diameters

SPECIFICATIONS

Technical Specifications

Size Designation Supplied ID, Min. (mm) Recovered ID, Max. (mm) Recovered Jacket Thickness (mm) Recovered Adhesive Thickness (mm) Recovered Total Wall (mm) Standard Length, m
8.0/2.0 8 2 1.80±0.30 0.55±0.20 2.35±0.35 1.22
9.0/3.0 9 3 2.00±0.30 0.55±0.20 2.55±0.40 1.22
13.0/4.0 13 4 2.30±0.30 0.55±0.20 2.85±0.40 1.22
16.0/5.0 16 5 2.30±0.30 0.60±0.20 2.90 ±0.50 1.22
22.0/6.0 22 6 2.50±0.40 0.60±0.25 3.10±0.50 1.22
28.0/6.0 28 6 2.70±0.40 0.70 ±0.25 3.40±0.50 1.22
33.0/8.0 33 8 2.80 ±0.40 0.80 ±0.25 3.60±0.60 1.22
38.1/12.0 38.1 12 3.10±0.50 0.80 ±0.25 3.90±0.60 1.22
43.2/12.0 43.2 12 3.50±0.50 0.80 ±0.25 4.30±0.70 1.22
55.0/16.0 55 16 3.60±0.50 0.80 ±0.25 4.40±0.70 1.22
65.0/19.0 65 19 3.60±0.50 0.80 ±0.25 4.40±0.70 1.22
75.0/22.0 75 22 3.60±0.50 0.80 ±0.25 4.40±0.70 1.22
85.0/25.0 85 25 3.60±0.50 0.80 ±0.25 4.40±0.70 1.22
95.0/30.0 95 30 3.60±0.50 0.80 ±0.25 4.60±0.70 1.22
105.0/30.0 105 30 3.80 ±0.60 0.80 ±0.25 4.60 ±0.70 1.22
120.0/39.0 120 39 3.80 ±0.60 0.80 ±0.25 4.60 ±0.70 1.22
130.0/40.0 130 40 3.80 ±0.60 0.80 ±0.25 4.60 ±0.70 1.22
140.0/42.0 140 42 3.80 ±0.60 0.80 ±0.25 4.60 ±0.70 1.22
160.0/50.0 160 50 3.80 ±0.60 0.80 ±0.25 4.60 ±0.70 1
180.0/65.0 180 60 3.80 ±0.60 0.80 ±0.25 4.60 ±0.70 1
200.0/69.0 200 69 3.80 ±0.60 0.80 ±0.25 4.60 ±0.70 1

Request Quotation

FAQS

Frequently Asked Questions

Find quick answers to common questions about our programs, admissions, eligibility, and application process to help you move forward with confidence.

Heat shrinkable tubing is used to insulate, seal, and protect cables, wire bundles, splices, terminations, busbars, and connector-to-cable transitions.
Medium wall tubing is used for LV cable insulation and protection. Heavy wall tubing is used for medium-voltage applications where stronger mechanical, environmental, abrasion, corrosion, and chemical protection is required.
Adhesive-lined heat shrink tubing has an inner adhesive layer that bonds to the surface during shrinking. It helps seal the connection against water, moisture, fluids, and other contaminants.
Shrink ratio shows how much the tubing reduces in diameter after heating. For example, 2:1, 3:1, and 4:1 tubing recover to a smaller size depending on the application and diameter difference.
Anti-tracking heat shrink tubing is used in low-voltage and medium-voltage termination and jointing kits for insulation, tracking resistance, erosion resistance, and protection against accidental flashover.
Stress controlled heat shrink tubing is used in medium-voltage terminations and joints to control electrical stress around the semiconducting layer end.
Busbar insulating heat shrink tubing is used on busbars in switchgear and substations to provide insulation protection and reduce the risk of short circuit and electrical leakage.
Selection depends on voltage level, cable or busbar size, shrink ratio, wall type, sealing requirement, operating temperature, and special needs such as anti-tracking, flame retardancy, halogen-free performance, or high-temperature resistance.

Download Catalogue