IPC for Earthing

Insulated Piercing Connectors (For Earthing) provide temporary grounding connections for Medium Voltage Covered Conductors (MVCC) during maintenance without removing conductor insulation. Available in single-bolt and double-bolt configurations for conductor sizes from 25 mm² to 150 mm², they feature an aluminium earthing ring for connecting grounding equipment.
MVCC Accessories
MV Covered Conductor
Overhead Power Lines
Temporary Grounding
Maintenance Safety
Electrical Earthing

Selection Summary

Application : Temporary Earthing of MV Covered Conductors

Conductor Range : 25–100 / 50–150 mm²

Contact Plates : Tinned Copper / Aluminium Alloy

Earthing Ring : Aluminium

Certificates & Approvals

BS EN 50397-2

Application Check

Is this product right for your application?

Application

Suitable?

Recommendation

Temporary Earthing of MV Covered Conductors
Yes
Use Earthing IPC
Grounding Connection During Maintenance
Yes
Use Earthing IPC with Compatible Grounding Equipment
Connection Without Removing Insulation
Yes
Use Insulation Piercing Connector
25–100 mm² Conductor Range
Yes
Select Compatible Variant
50–150 mm² Conductor Range
Yes
Select Compatible Variant
Single-Bolt Configuration
Yes
Select 1-Bolt Variant
Double-Bolt Configuration
Yes
Select 2-Bolt Variant
Earthing Ring Connection
Yes
Use Aluminium Earthing Ring
Other Conductor Sizes
Not Specified
Confirm Availability

SPECIFICATIONS

Technical Specifications

Product Code Conductor Range (mm2) Conductor dia. (mm) Number of Bolts
MVCC94008E 25-100 11.2 – 18.8 1
MVCC94013E 50-150 13.9 – 22.4 2

Request Quotation

FAQS

Frequently Asked Questions

Find quick answers to common questions about our programs, admissions, eligibility, and application process to help you move forward with confidence.

It provides a temporary grounding connection for Medium Voltage Covered Conductors during maintenance without removing the conductor insulation.
The available conductor ranges are 25–100 mm² and 50–150 mm².
The body is made from black high-strength engineering polymer, with tinned copper or aluminium alloy contact plates, galvanised steel fasteners, an aluminium, engineering polymer or composite shear nut, and an aluminium earthing ring.
No. The insulation-piercing contact points establish an electrical connection without removing the conductor insulation.
The connector is available in single-bolt and double-bolt configurations.
The product page specifies a short-circuit current withstand capacity of 10 kA for 1 second.
BS EN 50397-2 is the testing standard specified on the product page.

Download Catalogue